MIC600 Online Multi Gas Detector Eranntex

$350.00

Description

Multi Gas Detector

Product Description

  • The 2.5-inch high-definition color screen displays information such as real-time concentration, alarm, time, temperature, humidity, storage, and so on;
  • The menu interface adopted high-definition simulation graphics to display the function name of each menu.
  • Standard configuration is the data storage capacity for 100, 000 entries;
  • SD card storage function is an optional configuration, real-time storage, and fixed-time storage are supported, or only the data of the alarm concentration will be stored;
  • It is supported to use the local host to view, and delete data, and upload the data via RS485 interface to the computer for data analysis or printing.
  • The optional high-temperature high-humidity pretreatment system will be possible to detect the smoke gas at the temperature of 1300 ℃.
  • The detection of the gases at other temperatures can be customized.
  • Simultaneously display the concentrations of multiple types of gases, repeatedly display the concentration of single-channel gases in large font, and display the real-time curve.

Product Parameters

Gases to be detected
Hydrofluoric Acid,Phosgene     (HF/COCL2)
Application scenarios
All the cases which require the fixed installation, and online detection of gas concentrations such as petroleum, chemical,pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.
Detection range
0-1/10/100ppm. (other ranges can be customized)
Resolution
0.01ppm or 0.001ppm (0 ~ 10 ppm);0.01ppm (0 ~ 100 ppm),0.1ppm (0 ~ 1000 ppm),1ppm (0 ~ 10000 ppm or more),0.01 mg/l (0 ~ 200 mg/l),0.1% LEL,0.01%,0.001% Vol
Detection principle
Electrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, and so on, depending on the type ofgas, range, field environment, and user demand.
Allowable error
≤±2% F.S (other or higher precision levels can be customized)
Response time
T90≤30 seconds
Working environment
Temperature: -40 ℃ ~ + 70 ℃, humidity: ≤10 ~ 95% RH (regular)
Working environment
Temperature: -40 ℃ ~ + 70 ℃Humidity: ≤10 ~ 95% RH (regular)
Display method
A 2.5-inch high-definition color screen
Working voltage
12 ~ 30VDC direct current the standard power supply for a single piece of equipment is 24V, DC stabilized voltage switching power supply of1A or greater than 1A
Power supply reference
24V, 2.1A is possible to drive 40 units of toxic gas detector, or 15 units of flammable, infrared gas detector.
Optional items
Alarms; Wireless Transmission; Pretreatment System; SD Card; Temperature and Humidity Measurement; Accessory for connection with computer for monitoring.
Working method
Fixed type installation, online detection, diffusion type measurement
Protection level
IP66
Explosion-proof type
Explosion suppression type
Explosion-proof mark
ExdⅡCT6, certificate number: CNEx15.1283
Exterior dimensions
210×170×85mm (L×H×W)
Weight
1.8Kg
Standard accessories
Manual, qualification certificate, warranty card, outer packaging box
Gas DetectionFormulaMeasuring RangeWorking principleResolution
Combustible gasEXP0-100%LELCatalytic combustion0.1%LEL
OxygenO20-30%VOLElectrochemistry0.01%VOL
Carbon monoxideCO0-100PPMElectrochemistry0.01ppm
MethaneCH40-100%VOLInfrared0.01%VOL
Hydrogen sulfideH2S0-100PPMElectrochemistry0.01ppm
Nitrogen dioxideNO20-20PPMElectrochemistry0.01ppm
Nitric oxideNO0-250PPMElectrochemistry0.01ppm
Sulfur dioxideSO20-100PPMElectrochemistry0.01ppm
ChlorineCL20-20PPMElectrochemistry0.01ppm
Nitrogen oxideNOX0-100PPMElectrochemistry0.01ppm
AmmoniaNH30-100PPMElectrochemistry0.01ppm
HydrogenH20-1000PPMElectrochemistry0.1ppm
PhosphinePH30-20PPMElectrochemistry0.01ppm
Hydrogen chlorideHCL0-20PPMElectrochemistry0.01ppm
Chlorine dioxideCLO20-20PPMElectrochemistry0.01ppm
Hydrogen cyanideHCN0-50PPMElectrochemistry0.01ppm
Ethylene oxideETO0-100PPMElectrochemistry0.01ppm
OzoneO30-20PPMElectrochemistry0.01ppm
Nitrous oxideN2O0-100ppmInfrared0.01ppm
FormaldehydeCH2O0-20PPMElectrochemistry0.01ppm
EthyleneC2H20-100ppmThermal Conductivity0.01ppm
Fluorine gasF20-10PPMElectrochemistry0.01ppm
Hydrogen fluorideHF0-10PPMElectrochemistry0.01ppm
Carbon dioxideCO20-5000PPMInfrared1ppm
BenzeneC6H60-100PPMElectrochemistry0.01ppm
TolueneC7H80-100PPMElectrochemistry0.01ppm
PhosgeneCOCL20-1PPMElectrochemistry0.001ppm
Hydrogen bromideHBr0-20PPMElectrochemistry0.01ppm
NitrogenN20-100%VOLElectrochemistry0.01%VOL
Sulfur hexafluorideSF60-1000PPMThermal Conductivity0.1ppm
Sulfur hexafluorideSF60-1000PPMInfrared0.1ppm
PIDVOC0-100PPMPID photo ionization0.01ppm
FreonR22/R32/R134a0-1000PPMThermal conductivity0.1ppm
Dust ParticlesPM2.5/Pm10/etc0-100g/m3laser-semiconductor0.01g/m3
ArgonAR0-100%VOLThermal conductivity0.01%VOL
XenonXe0-100%VOLThermal conductivity0.01%VOL
Carbonyl chlorideCOCL20-100ppmElectrochemistry0.01ppm
SilaneSiH40-100ppmElectrochemistry0.01ppm
Methyl bromideCH3Br0-100ppm/0-200g/m3Infrared0.01ppm
Sulfuryl fluorideSO2F20-100ppm/0-200g/m3Infrared0.01ppm
ArsineAsH30-50ppmElectrochemistry0.01ppm
TetrahydrothiopheneTHT0-100mg/m3Electrochemistry0.01mg/m3

Real-time data upload

Signal Outputs

Powerful and Convenient Humanized Function

①Multiple alarm modes, and multi-directional and three-dimensional indication alarm states. It includes 2 sets of relay switch output, sound & light alarm (optional configuration), and display screen visual alarm. Alarm types include concentration alarm and failure alarms. Multiple alarm mode settings: low alarm, high alarm, interval alarm, and weighted average alarm.
②Zero-point automatic tracking; long-term use will not be affected by the zero drift.
③Multi-level calibration for target points can ensure the linearity and accuracy of the measurements.
④Log recording Record the calibration logs, repair logs, failure history, failure countermeasure solutions, sensor service life due reminder, and function of reminder for the time of next concentration calibration.
⑤Data recovery function; in case of misoperation, it is possible to select partial or full recovery.
⑥Mis-operation recognition function: automatic recognition and prevention of the concentration calibration misoperation, which is possible to avoid the poor performance that may be caused by human factors.
Infrared Remote Control①Standard configuration includes the infrared remote control, it is possible for one-key operation via the infrared remote control function key, which can achieve the operation without opening the cover under hazardous situations. such as: functions like modification of the alarm point, density calibration, zero-point calibration, noise reduction, restoring the factory setting, and so on.

Specification

About us Gaspanda.

Cooperation Clients

Cooperating Clients

Product Certifications

Certificate of Product

Packing & Delivery

FAQ
Q:Are you a trading company or manufacturer?
A:We are a professional manufacturer and exporter in China with over 15 years of experience with CE, ROHS, FCC, ISO, and 11 patents.
Q:What is the lead time?
A:Sample needs 1-2 days, mass production time needs 3-5 days for orders <=5000pcs.
Q:Do you have any MOQ limit?
A:We don't have a MOQ limit, 1 pc is also welcome.
Q:Do you offer a guarantee for the products?
A:Yes, we offer a 1-year guarantee and lifetime maintenance for the products.
Q:If I order a big quantity, Can I have a cheaper price?
A:We will reduce the price according to the specific quantity and your requirements for the product.

Reviews

There are no reviews yet.

Be the first to review “MIC600 Online Multi Gas Detector Eranntex”

Your email address will not be published. Required fields are marked *