Description
Fixed Methyl Mercatan Detector
Methyl mercaptan reacts easily with other substances to form sulfur-containing substances, which are the main raw materials for the synthesis of pesticides, pharmaceuticals, foodstuffs, and synthetic materials. Therefore, methyl mercaptan has a wide range of uses.
ET5-CH3SH, Fixed Methyl mercaptan detector has important applications in waste gas treatment. It can be used as a reducing agent to convert sulfur dioxide into hydrogen sulfide in exhaust gases. In addition, methyl mercaptan can also be used as a catalyst to promote the reduction of nitrogen oxides in exhaust gases.
The lethal concentration of methyl mercaptan is 5000 ppm (30 minutes) and its lethal concentration is 10000 ppm (10 minutes).
In the United States, the allowable workplace concentration for methyl mercaptan is 10 ppm (8-hour time-weighted average). In addition, the United States Occupational Safety and Health Administration (OSHA) has established a short-term exposure limit of 20 ppm for methyl mercaptan under no circumstances.
The concentration of methyl mercaptan gases can be detected regardless of whether the concentration is high or low through 24-hour online detection and real-time display of the data concentration of the hazardous site to play an early warning role in the safety of operations.
Key Feature
NO. | Product Features |
---|---|
1. | 2.4 inches LCD display,the gas type, unit, concentration, time can be showed on the screen. |
2. | 1-4 kinds of sensors can be function in any combination. |
3. | The gas concentration unit PPM,mg/m3,%VOL can be shifted quickly. |
4. | One press to restore factory setting, free from the bother of mis-operation. |
5. | Variety signal output model :4-20mA signal/RS485 signal/Two relays output/0-5V |
6. | Supports wireless signal transmission:Bluetooth transmission/Wireless transmission |
7. | Explosion-proof certification, and explosion-proof grade: Ex ia IIC T4 Ga. |
8. | With Self-calibration&zero calibration functions, makes the detection more accurate&reliable. |
9. | Chinese and English operation model. |
10. | With overvoltage protection,lightning protection,short-circuit protection,wrong connection protection,electrostatic prevention,magnetic-field interference prevention |
Technical Parameters
Mode | ET5-CH3Sh (Can do customized Model and logo and company label) |
Detection gas | Methyl Mercaptan Gas (For more different gases pls check the sensor list below) |
Measuring range | 0-1/10/100/500/1000ppm,10000ppm,30000ppm;0-5%vol,30%vol,100%vol (for option)(Please consult and confirm the measuring range before placing an order.) The unit can be switched freely. Units for optional: ppm, mg/m3, Vol%, LEL%, ppb, mg/L. |
Resolution | 0.001ppm(0-1ppm);0.01ppm(0-100ppm);0.1ppm(0-1000ppm);1ppm(0-10000ppm);0.01%Vol or 0.001%Vol (0-100%vol) |
Working principle | Electrochemical, infrared, catalytic combustion, thermal conductivity, semiconductor, PID, etc.Depends on measuring range, field environment, and customer requirements. |
Detection Pattern | Diffusion, Pipeline, Circulation, and Pumping is available, Online detection |
Scalable gas | 1-6 kinds of sensors can function in any combination, please refer to the sensor parameter |
Accuracy | ≤±1% F.S. (Customizable with higher accuracy) |
Linearity Error | ≤±1% |
Repeatability | ≤±1% |
Alarm | Sound and light alarm |
Reaction time | ≤10s(T90) |
Relay | Two relays output, Contact rating24VDC 3A/220VAC 3A |
Material | Aluminum; Explosion and corrosion-proof |
Connection | 3/4″NPT,1/2″NPT |
Working environment | Temperature: -40℃~+70℃ Humidity: ≤10~95%RH (no condensation)【Can select Temperature&Humidity sensor】 |
Data storage | Auto storage、 manual storage, Up to 100,000 group data can be storage, and history data can be shown at the display |
Communication interface | USB (Charging and communication), with charging protection function, support USB hotplug |
Interface language | English |
Explosion-proof | ExdII CT6, Certification Number of Explosion-proof: CNEx10.1807 |
Protection | IP66 |
Dimensions/ Net weight | 200×160×80mm(L×W×H)1.5 Kg(Net weight) |
Pressure | -30Kpa ~ 100Kpa |
Standard accessories | Case、User manual、Certification、USB charger+cable、Calibration cover |
Optional accessories | Filter tip: filter water vapor and dust, change regularly according to the site environment high-temperature sampling handle: 400°C, 800°C, 1300°C high-temperature sampling handle (to detect high-temperature sample gas) |
Optional functions | RS485 signal output, integrated built-in printer, external wireless Bluetooth printer, one-key SOS call, wind speed detection, pressure difference detection environmental temperature and humidity detection: temperature -40℃~+70℃, accuracy 0.5℃; humidity 0~100%RH, accuracy 3%RHWireless data transmission: RoLa module, Bluetooth module, WiFi module, 443M module, Zig-Bee module (free computer software/cloud platform/mobile APP remote monitoring data)Storage function: optional 16G or larger capacity SD card storage |
Output signal | Variety signal output model :4-20mA signal/RS485 signal/Two relays output/0-5V |
Common Detectable Gases
Gas Detection | Formula | Measuring Range | Working principle | Resolution |
---|---|---|---|---|
Combustible gas | EXP | 0-100%LEL | Catalytic combustion | 0.1%LEL |
Oxygen | O2 | 0-30%VOL | Electrochemistry | 0.01%VOL |
Carbon monoxide | CO | 0-100PPM | Electrochemistry | 0.01ppm |
Methane | CH4 | 0-100%VOL | Infrared | 0.01%VOL |
Hydrogen sulfide | H2S | 0-100PPM | Electrochemistry | 0.01ppm |
Nitrogen dioxide | NO2 | 0-20PPM | Electrochemistry | 0.01ppm |
Nitric oxide | NO | 0-250PPM | Electrochemistry | 0.01ppm |
Sulfur dioxide | SO2 | 0-100PPM | Electrochemistry | 0.01ppm |
Chlorine | CL2 | 0-20PPM | Electrochemistry | 0.01ppm |
Nitrogen oxide | NOX | 0-100PPM | Electrochemistry | 0.01ppm |
Ammonia | NH3 | 0-100PPM | Electrochemistry | 0.01ppm |
Hydrogen | H2 | 0-1000PPM | Electrochemistry | 0.1ppm |
Phosphine | PH3 | 0-20PPM | Electrochemistry | 0.01ppm |
Hydrogen chloride | HCL | 0-20PPM | Electrochemistry | 0.01ppm |
Chlorine dioxide | CLO2 | 0-20PPM | Electrochemistry | 0.01ppm |
Hydrogen cyanide | HCN | 0-50PPM | Electrochemistry | 0.01ppm |
Ethylene oxide | ETO | 0-100PPM | Electrochemistry | 0.01ppm |
Ozone | O3 | 0-20PPM | Electrochemistry | 0.01ppm |
Nitrous oxide | N2O | 0-100ppm | Infrared | 0.01ppm |
Formaldehyde | CH2O | 0-20PPM | Electrochemistry | 0.01ppm |
Ethylene | C2H2 | 0-100ppm | Thermal Conductivity | 0.01ppm |
Fluorine gas | F2 | 0-10PPM | Electrochemistry | 0.01ppm |
Hydrogen fluoride | HF | 0-10PPM | Electrochemistry | 0.01ppm |
Carbon dioxide | CO2 | 0-5000PPM | Infrared | 1ppm |
Benzene | C6H6 | 0-100PPM | Electrochemistry | 0.01ppm |
Toluene | C7H8 | 0-100PPM | Electrochemistry | 0.01ppm |
Phosgene | COCL2 | 0-1PPM | Electrochemistry | 0.001ppm |
Hydrogen bromide | HBr | 0-20PPM | Electrochemistry | 0.01ppm |
Nitrogen | N2 | 0-100%VOL | Electrochemistry | 0.01%VOL |
Sulfur hexafluoride | SF6 | 0-1000PPM | Thermal Conductivity | 0.1ppm |
Sulfur hexafluoride | SF6 | 0-1000PPM | Infrared | 0.1ppm |
PID | VOC | 0-100PPM | PID photo ionization | 0.01ppm |
Freon | R22/R32/R134a | 0-1000PPM | Thermal conductivity | 0.1ppm |
Dust Particles | PM2.5/Pm10/etc | 0-100g/m3 | laser-semiconductor | 0.01g/m3 |
Argon | AR | 0-100%VOL | Thermal conductivity | 0.01%VOL |
Xenon | Xe | 0-100%VOL | Thermal conductivity | 0.01%VOL |
Carbonyl chloride | COCL2 | 0-100ppm | Electrochemistry | 0.01ppm |
Silane | SiH4 | 0-100ppm | Electrochemistry | 0.01ppm |
Methyl bromide | CH3Br | 0-100ppm/0-200g/m3 | Infrared | 0.01ppm |
Sulfuryl fluoride | SO2F2 | 0-100ppm/0-200g/m3 | Infrared | 0.01ppm |
Arsine | AsH3 | 0-50ppm | Electrochemistry | 0.01ppm |
Tetrahydrothiophene | THT | 0-100mg/m3 | Electrochemistry | 0.01mg/m3 |
Customer Scenarios
Application
- Furniture, flooring, wallpaper, paint, gardening, interior decoration and renovation, dyes, paper, pharmaceutical, medical, food, and corrosion.
- Disinfection, chemical fertilizers, resins, adhesives and pesticides, raw materials, samples, process and breeding plants, waste treatment plants, and perm places.
- Biopharmaceutical production workshops, home environment, livestock breeding, greenhouse cultivation, storage and logistics, brewing fermentation, agricultural production, etc.
Cooperating Clients
Product Certifications
Packing & Delivery
FAQ | |
---|---|
Q: | Are you a trading company or manufacturer? |
A: | We are a professional manufacturer and exporter in China with over 15 years of experience with CE, ROHS, FCC, ISO, and 11 patents. |
Q: | What is the lead time? |
A: | Sample needs 1-2 days, mass production time needs 3-5 days for orders <=5000pcs. |
Q: | Do you have any MOQ limit? |
A: | We don't have a MOQ limit, 1 pc is also welcome. |
Q: | Do you offer a guarantee for the products? |
A: | Yes, we offer a 1-year guarantee and lifetime maintenance for the products. |
Q: | If I order a big quantity, Can I have a cheaper price? |
A: | We will reduce the price according to the specific quantity and your requirements for the product. |